Apply to a clean, dry surface. Temperature should be above 40F°. At temperatures less than 60° precipitation or freezing conditions should not be expected for at least 48 hours. At temperatures above 60 F° precipitation should not be expected for at least 2 to 3 hours.
Surfaces
with mold or algae growth should first be pressure washed with an oxygen bleach solution, rinsed and dried.

can be applied by spray, roller or brush.
Coverage for NuKlear Saturating Primer
should be at a maximum rate of 1/2 gallon per 200 square feet per coat. Material should be applied in the shade or the cooler part of the day. Avoid direct sun. If the first coat is drying in less than ten minutes add refresher and/or water. Avoid dry lapping. NuKlear finish coat is usually reduced 50% with water. Apply after
the primer coat has completely dried. If you want an extra-heavy coating don't reduce with water.
Studies have shown that NuKlear® applied at 240 square feet per gallon will provide waterproofing protection in excess of four years in a Midwestern climate. Your mileage may vary depending on climate.
|